Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 342-348, 2020.
Article in Chinese | WPRIM | ID: wpr-868611

ABSTRACT

Objective:To analyze the efficacy of chest wall boost radiotherapy in stage T 4 breast cancer patients after modified radical mastectomy. Methods:A retrospective analysis was performed on the data of 148 stage T 4 breast cancer patients who were admitted from 2000 to 2016 and received radiotherapy after modified radical mastectomy. There were 57 cases in the chest wall boost radiotherapy group and 91 cases in the conventional dose group. Radiotherapy was performed by conventional+ chest wall electron beam, three-dimensional conformal+ chest wall electron beam, intensity modulated radiotherapy+ chest wall electron beam irradiation. EQD 2 at the boost group was >50Gy. All patients received neoadjuvant chemotherapy. Kaplan-Meier method was used to analyze survival; Logrank was used to test differences; and Cox model was used to do multivariate prognostic analysis. Results:The median follow-up time was 67.2 months. The 5-year rates of chest wall recurrence (CWR), locoregional recurrence (LRR), disease-free survival (DFS), and overall survival (OS) were 9.9%, 16.2%, 58.0%, and 71.4%, respectively. The 5-year rates of CWR, LRR, DFS, and OS with and without chest wall boost radiotherapy were 14% vs. 7%, 18% vs. 15%, 57% vs. 58%, 82% vs. 65%( P>0.05), respectively. Multivariate analysis showed that chest wall boost radiotherapy had no significant effect on prognosis ( P>0.05). Among 45 patients in the recurrent high-risk group, boost radiotherapy seemed to have higher OS rate ( P=0.058), DFS rate ( P=0.084), and lower LRR rate ( P=0.059). Conclusions:Stage T 4 breast cancer patients had strong heterogeneity. Chest wall boost radiotherapy did not apparently benefit all patients. For patients with 2-3 high risk factors including positive vascular tumor embolus, pN 2-N 3, and hormone receptor negative, chest wall boost radiotherapy showed a trend of improving efficacy.

2.
Chinese Journal of Radiation Oncology ; (6): 949-952, 2019.
Article in Chinese | WPRIM | ID: wpr-800199

ABSTRACT

Although the internal mammary is the lymphatic drainage site for breast cancer, whether postoperative radiotherapy needs to be irradiated remains controversial. In recent years, several random studies have discussed internal mammary radiotherapy to varying degrees and no evidence has obtained that internal mammary radiotherapy bring clinical benefits to overall survival. In clinical practice, internal mammary prophylactic radiotherapy should maintain the balance among the risk of tumor recurrence, prescription dose and radiotherapy techniques to avoid the increased risk of radiotherapy-related death that offsets the possible survival benefits.

3.
Chinese Journal of Radiation Oncology ; (6): 504-508, 2018.
Article in Chinese | WPRIM | ID: wpr-708224

ABSTRACT

Objective To analyze the correlation between treatment time and radiotherapy plan of deep inspiration breath-hold (DIBH) technique for the whole breast irradiation (WBI) in the left breast cancer after breast-conserving surgery,verify the inter-fractional reproducibility of radiotherapy,observe the heart location and dosimetric changes and calculate the effect of DIBH upon the WBI setup error after the surgery.Methods We prospectively enrolled 15 patients with left breast cancer undergoing WBI after breast-conserving surgery,who met the requirement of D1BH.Treatment time was recorded,its correlation with the number of field and monitor unit was analyzed.Inter-fractional setup errors and PTV delineation were calculated using cone beam CT (CBCT).The accuracy of the position and dose of the heart during radiotherapy was verified by the imaging fusion of CBCT and CT images.The variables among groups were analyzed by non-parametric Firedman test.Results The average treatment time of DIBH radiotherapy was 4.6 minutes.The treatment time was correlated with the maximal and total number of sub-fields and total monitor units.During DIBH treatment,the mean cardiac displacement volume was 19.1 cm3(3.8%).The mean cardiac dose difference between CBCT and planning CT was 5.1 cGy,and there was no significant difference in the heart V5-V30.The mean inter-fractional system setup error (∑) and random setup error (σ) in the left-right (x),superior-inferior (y) and anterior-posterior (z) direction were ∑x 1.9 mm,∑y 2.1 mm,∑z 2.0 mm,σx 1.3 mm,σy 1.3 mm,σz 1.4 mm,respectively.The corresponding minimal margins for setup error were 5.7 mm,6.2 mm and 6.0 mm,respectively.Conclusion DIBH for WBI after breast-conserving surgery does not significantly prolong the treatment time.Treatment time is related to treatment plan.DIBH yields high inter-fractional reproducibility and protects the heart.

4.
Chinese Journal of Radiation Oncology ; (6): 281-288, 2018.
Article in Chinese | WPRIM | ID: wpr-708182

ABSTRACT

Objective To study the effect of deep inspiration breath-hold(DIBH)technique on the heart dose in whole breast irradiation(WBI)for left breast cancer after breast-conserving surgery, and to investigate the anatomical factors for heart dose. Methods Fifteen patients with left breast cancer who received WBI after breast-conserving surgery and met breathing control requirements were prospectively enrolled as subjects. Simulated CT scans were performed during free breathing(FB)and DIBH. The WBI plans were optimized based on DIBH images.The position,volume,and radiation doses to the heart and lung were compared between the status of FB and DIBH. Correlation of heart dose with various anatomical factors was analyzed in FB status. Between-group comparison of categorical data was made by nonparametric Wilcoxon rank test.A two-variable correlation analysis was made by the Pearson method.Results There was no significant difference in heart volume between the status of FB and DIBH(P=0.773).The volume of both lungs was significantly larger in DIBH status than in FB status(P=0.001). The mean and maximum doses and V5-V40for the heart,left anterior descending coronary artery,left ventricle,right ventricle,and left lung were significantly lower in DIBH status than in FB status(all P<0.05). The greater DIBH increased the lung volume,the greater the mean heart dose decreased. In FB status,the left breast volume,heart-to-lung volume ratio,distance between the inferior margins of breast and heart,and maximum heart margin distance showed a linear correlation with heart dose. Particularly, the heart-to-lung volume ratio and maximum heart margin distance were independently correlated with heart dose. Conclusions DIBH technique in WBI for left breast cancer after breast-conserving surgery significantly reduces heart and lung doses compared with FB. Changes in lung volume are the basis for improving the relative anatomical location of the heart. The heart-to-lung volume ratio and maximum heart margin distance may provide a reference for DIBH technique.

SELECTION OF CITATIONS
SEARCH DETAIL